Protector Lamp's Flame Safety Lamps have been in constant use since 1873 and the GR6S Garforth miners lamp is the approved method of checking for firedamp
Thursday, September 20, 2007
SL LIGHTING
from what you say you have an SL (side lit) lamp with a type 6 top.
the sl or workmans lamp was lit in the lamp room by a current of approx 4 volts. if you strip it down you will see a series of insulating washers.
the current was applied to the side of the vessel and the glass plate. it fed to the platinum wire which glowed red sufficient to light the fuel in the wick.
you couls chop the top off the locking standard wire, enabling you to unscrew the bonnet and light with a naked flame.
59 is for 1959.
regards david
Trevor Funnell wrote: Hi, I've just acquired a Type 6 lamp which I can't work out how to light. The serial plate on the bonnet only mentions that it's a type 6 and there are no other visible markings that resemble serial The Brass fuel tank has been stamped 33/4813 but this appears to have been done after manufacture, next to the wick are what appear to be two screws holding a wire heating element (1cm or so of fuse type wire)The glass bears a Crown type logo with "MFP" in the centre above which is an oval with "M (something)" flanked by "5H 1/4" to the left and "59" I had hoped to use the lamp occasionally as well as keeping it for its ornamental value, I noticed on your web site the odd mention of HT being used to light certain versions of lamp, is mine one of these? and if so am I likely to be able to light it (I would consider minor modifications if it didn't ruin the over all appearance of the lamp.
Wednesday, July 25, 2007
OLYMPIC TORCH RELAY ARRIVES AT JFK
Tuesday, July 17, 2007
FLAME OF HOPE ARRIVES AT JFK
Friday, July 13, 2007
SL lamp information
the SL for side lit or workmans lamp was used alongside the relighters. workman were not allowed to relight underground.they started phasing them out in the late 70's.
the SL was lit by a low voltage electric current in the lamp room.
the principle of the davy gauze is that the flame will burn inside the gauze but the size of the mild steel gauze ie; 28swg wire with 28 holes per inch sufficiently dissipates the heat so as not to ignite methane or firedamp outside the gauze. so when methane is present it burns in a flame on top of the lamp flame and the height gives the percentage of methane present and thus warns of an explosive atmosphere.
re lighting underground if you relight a lamp in an explosive atmosphere it will detonate and cause an explosion.
re the fuel tank or vessel, the felts inside are designed to soak up the fuel. the filling technique is to fill to the top leave 5 minutes then stand the vessel upside down to drain off the excess fuel. whats left will be sufficient to last 8-12 hours ie a normal shift.
most older pit lamps leak ad it is very difficult to reseal. but if you follow the above you should be ok.
regards david
Thank you VERY much for the quick and thorough answer David. I really appreciate it!
Mine is the one with the platinum wire lighter - were those in use before or after the flint ones?
Also - I was wondering a bit about what actually made the lamps safe in gas - is it because the gauzes makes for an increae of nitrogen making the mixture of gases inside the lamp less flameable?
I have failed to find a really good explanation for how the lamp actually works among all info on the net.
One last thing about my lamp; There seems to be a small leak in the bottom soldering on the tank - Do you think I could blow-torch it to seal it again? Or should I use some chemical seal ? I wouldn?t want to burn the felt inside...
Thanks again for the answer!
Regards,
Ola
Wednesday, July 11, 2007
TYPE 6 LAMP HELP
the type 6 is a deputies relighter lamp which we supplied in bulk from nationalisation in 1947 to the ministry of power subsequently the national coal board and then british coal.the type 6 began to be replaced by the garforth/GR6S lamp from 1965.
the number 61 stamped on the bonnet is the miner check number. checks are handed in at the lift gate so they know who is underground.
50/ is for made in 1950.
the fuel tank or vessel is packed with felt pads to absorb the fuel,colzalene or relighter spirit which is similar to petrol. you can use petrol or ronson or zippo lighter fuel. in addition there is a long section of wick coming up to the bottom of the wick tube. this must not be removed. on top of this fits the trimming wick approx 1" long which is replaced regularly in the pits.
the felt pads and wick dry out with lack of use.
best policy is to leave it submerged in a can of petrol for a day or two.
the reason paraffin is not used is it will not light with the spark ignition, it needs a naked flame. as the lamp is a flame trap and self extinguishing if dismantled a flame cannot be introduced.
the cracks in the wick tube will not help but it shiuld still burn.
it is called a mag lock bceause it needs magnet to pull down the sprung metal pin.
the innstruction manual comes in the service pack which you can buy online at www.protectorlamp.co.uk
good luck.
regards david mather
Ola Dahlbom wrote:
Hi!I realize you probably get a bunch of these questions but I´d very much appreciate it if you might help me out a bit:Firts of all the age.My lamp is stamped no. 61 on the bonnet - I gather this is just a serial?On the bottom plate just beside the sixth locker pin which goes up in the bonnet and locks it, is stamped: 50/4026G does this tell you anything?About the tank:Is it filled with cotton? If I look down the wick-tube, after removing the wick, it looks like another wick is stuck some 3/4 down. I put a small screwdriver down the tube and pushed and it´s very hard.I filled the tank with parafine and it runs for a few minutes then it seems it´s not getting enough fuel and starts burning the wick. Is it the fuel that´s wrong?I also noted that the wick tube is broken; two small cracks runs at each side from the top to near the bottom - does this make for bad capillary force in the wick?And last: How ist the lock suppose to work? Is it merely a push-spring bolt that´s supposed to go through the hole in the lock? If so - Why is it called a magnet lock?Again, I hope you don´t mind these questions - I really want my beautiful lamp to work!Thanks and regards,Ola DahlbomP.S.Is the a manual for this type of lamp? On the web?
Thursday, July 05, 2007
International Mining Memorabilia Fair France
International
Mining Memorabilia Fair
October 14 2007 From 8am to 5pm
Bully les mines France
Miner's lamps, Taillettes, Medals, Tools, Clothing,
Bars, Minerals, Gaillettes, Postcards, Stamps,
Documents, Photographs, films etc.
OLYMPIC TORCH RELAY ARRIVES IN UK
THE OLYMPIC FLAME OF THE SPECIAL OLYMPICS TORCH RELAY LANDED AT EAST MIDLANDS AIRPORT THIS MORNING ON A LUFTHANSA MD11 ON ROUTE FROM COLOGNE. THE FLAME CARRIED IN 2 PROTECTOR TORCH RELAY LAMPS WAS THEN BEING DRIVEN TO LONDON TO BE PRESENTED TO THE MAYOR KEN LIVINGSTONE.
FOR MORE INFO ON THE TORCH RUN CLICK ON THE PHOTO
Wednesday, July 04, 2007
Tuesday, May 29, 2007
PROTECTOR LAMP GOES YOU TUBE
USE THESE LINKS
PROTECTOR LAMP SERVICING
PROTECTOR LAMP SERVICING 2
protectorlamp.com
Monday, May 14, 2007
Lamp Presentation
Thursday, May 10, 2007
Law Enforcement Torch Run® for Special Olympics
Three uniformed officers and another volunteer,posing outside of the stadium at Iowa State University where Opening Ceremonies for the 2006 USA National Special Olympics Games were held. The night this picture was taken, the Final Leg team, made up of police officers from around the country, ran with the Flame into the ceremony and lit the cauldron to mark the start of the Games.
The officers are holding a Protector Torch Relay Lamp and a Koehler Bright Star Lamp.
for more on Special Olympics click this link
Wednesday, May 09, 2007
Pan American Games Rio 2007 Torch Relay
XV Pan American Games Rio 2007
Special Olympics Shanghai Torch Relay 2007
the protector torch relay lamp will be used to carry the flame on DHL aircraft.
Summer Games 2007
Friday, May 04, 2007
CLEARWELL CAVES TRIAL OUR NEW CAP LAMP
Clearwell Caves, the Royal Forest of Dean's
Iron Mining Museum is currently using one
of our latest cap lamps.
for more information on
clearwell click this link
HATFIELD COLLIERY
POWERFUELS RECENTLY REOPENED HATFIELD COLLIERY IS EXPANDING RAPIDLY AND NOW EMPLOYS 200 MEN.
FOR MORE INFORMATION GO TO THE ENERGY BLOG
Monday, April 30, 2007
Wednesday, April 25, 2007
Tuesday, March 06, 2007
Beamish to create lamp room
beamish museum in durham are to create an authentic miners lamp room from the early 20th century.
chris scott from beamish along with dave harker a friend of the museum and a respected lamp collector visited the protector lamp factory in eccles to look at original lamp room equipment and catalogues.
for more about beamish museum click this link
CAP LAMP TRIAL AT WINSFORD ROCK SALT MINE
THANKS TO MINE ENGINEER MICHAEL STRASSBURGER FOR A TOUR OF SALT UNIONS ROCK SALT MINE AT WINSFORD CHESHIRE.
MICHAEL AND HIS TEAM WILL BE TRIALLING THE LATEST LED CORDLESS CAP LAMP FROM KSE
TO FIND OUT MORE ABOUT SALT UNION AND THE MINE CLICK HERE